NHTSA DATA SNAPSHOT · SEP 21 2026MODEL MATCH ≠ VIN MATCHCHECK A VIN AT NHTSA ↗
RECALLROADTHE CAMPAIGN RECORD

MODEL-YEAR RECALL REPORT

2016 Gillig Low Floor recalls

NHTSA's September 21, 2026 snapshot lists 20 safety recall campaigns for the 2016 Gillig Low Floor, spanning 12 component groups. A model match does not confirm that a specific VIN is included.

Official source: NHTSA recall campaign file · Snapshot September 21, 2026

URGENT CAMPAIGN FLAG

NHTSA records include a Do Not Drive advisory for at least one campaign associated with 2016 Gillig Low Floor. Open the campaign and verify the VIN before operating or parking the vehicle.

Distinct campaigns20not VIN-specific
Component groups12distinct top-level categories
Latest recordApril 25, 2022report received
VIN resultNot checkeduse official lookup

01 / OFFICIAL CAMPAIGNS

2016 Gillig Low Floor recall campaigns

The 2016 Gillig Low Floor report contains 20 distinct NHTSA campaigns; the most recently received record is campaign 22V276000 dated April 25, 2022.
DO NOT DRIVE
Component
POWER TRAIN
Report received
September 29, 2016
Potential units
143campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain model year 2016 Low Floor transit buses manufactured May 26, 2016, to September 26, 2016. The affected buses have axles that may have insufficient grease at the wheel ends, possibly resulting in bearing failure.

Why it matters: Bearing failure may increase the risk of a crash.

Remedy

Gillig service centers or the fleet services for the bus owners will inspect the wheel bearings and add grease as necessary, free of charge. The recall began on October 5, 2016. Owners may contact Gillig customer service at 1-800-735-1500. Note: Gillig is advising that vehicles with the affected axles are removed from operation until the recall has been remedied.

Owner notification: October 5, 2016 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 22V276000

Component
ELECTRICAL SYSTEM
Report received
April 25, 2022
Potential units
592campaign-wide
Defect and consequence

Defect: Gillig, LLC (Gillig) is recalling certain 2014-2021 Low Floor transit buses. The rear-mounted ultracapacitors may allow the engine to be started when the master battery disconnect switch is in the "OFF" position.

Why it matters: The engine may be started unexpectedly, increasing the risk of injury to anyone nearby the engine compartment during maintenance operations.

Remedy

Dealers will update the software for the buses equipped with the Vanner Ultracapacitor system, and conduct a hard rewire for the buses equipped with the KBI system, free of charge. Owner notification letters were mailed on June 22, 2022. Owners may contact Gillig's customer service at 1-510-264-5073 for 1-800-735-1500.

Owner notification: June 22, 2022 · Filing manufacturer: Gillig, LLC

CAMPAIGN

NHTSA 20V392000

Component
STEERING
Report received
July 2, 2020
Potential units
531campaign-wide
Defect and consequence

Defect: Gillig, LLC. (Gillig) is recalling certain 2013-2020 hybrid and all-electric Low Floor buses equipped with a steering system that uses a high-voltage electric motor and hydraulic pump assembly to provide power steering assist. The shaft coupling between the motor and pump may fail and cause a loss of hydraulic power steering assist.

Why it matters: A loss of power steering assist may increase the risk of crash.

Remedy

Gillig will notify owners, and dealers will replace the motor-pump assemblies, free of charge. The recall began August 13, 2020. Owners may contact Gillig customer service at 1-800-735-1500.

Owner notification: August 13, 2020 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 20V179000

Component
ELECTRICAL SYSTEM
Report received
March 25, 2020
Potential units
8,224campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain 2012-2020 Low Floor buses. The circuit breaker ratings on the DEF Line Heater circuit and the Aftertreatment-Ignition circuit may be higher than the rating for the wire and connector.

Why it matters: With the improper circuit breaker rating, an electrical short in either of these circuits may increase the risk of a fire.

Remedy

Gillig will notify owners, and dealers will replace the circuit breakers, free of charge. The recall began April 24, 2020. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

Owner notification: April 24, 2020 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 19V193000

Component
EXTERIOR LIGHTING
Report received
March 8, 2019
Potential units
965campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain 2014-2019 Low Floor buses. Uncovered electrical terminals in the headlight power circuit may short circuit to ground, causing a loss of headlights.

Why it matters: A loss of headlights can reduce the driver's ability to see, increasing the risk of a crash.

Remedy

Gillig has notified owners, and dealers will install new back covers on the headlight buckets, free of charge. The recall began April 1, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

Owner notification: April 1, 2019 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 19V059000

Component
STEERING
Report received
January 28, 2019
Potential units
3,659campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain 2016-2018 Low Floor buses. The ball stud of the steering system draglink may not have been properly tightened.

Why it matters: If the ball stud is insufficiently tightened, the ball stud may wear, resulting in reduced handling and stability, increasing the risk of crash.

Remedy

Gillig will notify owners, and dealers will inspect and correct the ball stud tightness, as necessary, free of charge. The recall began March 20, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

Owner notification: March 20, 2019 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 18V886000

Component
STRUCTURE
Report received
December 12, 2018
Potential units
30campaign-wide
Defect and consequence

Defect: Gillig, LLC (Gillig) is recalling certain 2016-2017 Gillig Low Floor transit buses. As built, one of the emergency exit windows may not be able to be easily used in the event of an emergency. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 217, "Bus Emergency Exits and Window Retention and Release.".

Why it matters: An obstructed emergency exit can hinder passengers from vacating the bus in the event of an emergency, increasing the risk of injury.

Remedy

Gillig will notify owners, and dealers will move one of the emergency exit windows to an unobstructed location, free of charge. The recall began February 22, 2019. Owners may contact Gillig's customer service at 1-510-264-5073 or 1-800-735-1500.

Owner notification: February 22, 2019 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 18V789000

Component
PARKING BRAKE, SERVICE BRAKES, AIR
Report received
November 9, 2018
Potential units
4,469campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain 2013-2018 Gillig Low Floor transit buses equipped with disk brakes. The spring cage bolts on the air brakes may not be sufficiently tightened, reducing the effectiveness of the parking brake.

Why it matters: Loose cage bolts may result in the bus rolling away when in the park position or a loss of braking ability if the service brake air pressure is lost while moving. Either condition may increase the risk of a crash.

Remedy

Gillig will notify owners, and dealers will tighten the spring cage bolts, free of charge. The recall began December 10, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

Owner notification: December 10, 2018 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 18V511000

Component
EXTERIOR LIGHTING
Report received
August 9, 2018
Potential units
178campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain 2012-2018 Gillig Low Floor vehicles. The front and rear turn signals on these vehicles may flash at different rates, potentially confusing other drivers of the vehicle's intention. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment.".

Why it matters: The mismatched flashing may confuse other drivers, increasing the risk of a crash.

Remedy

Gillig will notify the owner of the buses, and dealers will reprogram the turn signals with new software, free of charge. The recall began August 30, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

Owner notification: August 30, 2018 · Filing manufacturer: Gillig LLC

Component
EXTERIOR LIGHTING
Report received
June 20, 2018
Potential units
25,579campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment.".

Why it matters: The reduced visibility of the turn signals can increase the risk of a crash.

Remedy

Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

Owner notification: August 2, 2018 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 17V559000

Component
STEERING
Report received
September 8, 2017
Potential units
108campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain 2013-2016 Hybrid and all Electric Low Floor buses with electro-hydraulic power steering assist. The coupler between the high-voltage electric motor and hydraulic steering pump shafts may fail, resulting in a loss of power steering assist.

Why it matters: A loss of power steering assist will cause the need for increased steering effort, increasing the risk of a crash.

Remedy

Gillig will notify owners, and dealers will replace the steering motor-pump assemblies, free of charge. The recall began on October 24, 2017. Owners may contact Gillig customer service at 1-800-735-1500.

Owner notification: October 24, 2017 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 17V519000

Component
SEAT BELTS
Report received
August 23, 2017
Potential units
3,432campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain 2017-2018 Low Floor transit buses, equipped with Recaro Commercial Bus Driver Seats. In the affected seats, the seat belt buckle may be stuck in the locked position, preventing the seat belt tongue from being able to be inserted and locked.

Why it matters: If the seat belt cannot be latched, the bus may be operated without the seat belt being used, increasing the risk of injury in the event of a crash.

Remedy

Gillig will notify owners and work with the supplier to replace the buckles, free of charge. The recall began on October 4, 2017. Owners may contact Adient-Recaro at 1-248-484-3250 or Gillig Service at 1-800-735-1500.

Owner notification: October 4, 2017 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 17V263000

Component
SUSPENSION
Report received
April 19, 2017
Potential units
2,604campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain 2015-2016 Low Floor transit buses equipped with Norgren-brand suspension kneeling modules. The suspension kneeling modules on these vehicles have snap rings on the solenoid valve pistons which may not have been fully inserted and seated during assembly, potentially affecting the suspension air bag pressure and the vehicle's suspension height.

Why it matters: An unexpected loss of suspension air bag pressure while driving would result in an abrupt reduction in suspension height, potentially increasing the risk of a crash. A loss of suspension air bag pressure could also occur during vehicle servicing, increasing the risk of injury to maintenance personnel.

Remedy

Gillig will notify owners and pay fleets to inspect the front and rear kneeling modules. A snap ring reset tool will be provided free of charge to permanently seat the snap ring in the intended groove. The recall began on June 2, 2017. Owners may contact Gillig customer service at 1-800-735-1500.

Owner notification: June 2, 2017 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 17V156000

Component
VISIBILITY/WIPER
Report received
March 9, 2017
Potential units
2,732campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain 2016-2017 Low Floor transit buses. The affected vehicles have wiper arms that can crack where they mount to the wiper motor causing the wiper arms to bend or detach from the vehicle.

Why it matters: A loss of wiper function can reduce the driver's visibility, increasing the risk of a crash.

Remedy

Gillig will notify owners, and dealers will replace the affected wiper arms, free of charge. The recall began on March 31, 2017. Owners may contact Gillig customer service at 1-800-735-1500.

Owner notification: March 31, 2017 · Filing manufacturer: Gillig LLC

Component
EXTERIOR LIGHTING
Report received
February 24, 2017
Potential units
17,056campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment.".

Why it matters: The reduced visibility of the turn signals may increase the risk of a crash.

Remedy

Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.

Owner notification: June 7, 2019 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 17V099000

Component
EXTERIOR LIGHTING
Report received
February 14, 2017
Potential units
2,787campaign-wide
Defect and consequence

Defect: Gillig, LLC (Gillig) is recalling certain 2016-2017 Low Floor transit buses. These vehicles have front LED turn signals with integrated side reflex reflectors that may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment.".

Why it matters: A bus that has reduced visibility to other drivers or pedestrians has an increased risk of a crash.

Remedy

Gillig will notify owners and will replace the LED turn signal/reflector units, free of charge. The recall is expected to begin March 31, 2017. Owners may contact Gillig customer service at 1-800-735-1500.

Owner notification: March 31, 2017 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 16V931000

Component
FUEL SYSTEM, OTHER
Report received
December 23, 2016
Potential units
451campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain model year 2015-2016 Low Floor compressed natural gas (CNG) transit buses manufactured September 1, 2015, to December 5, 2016, equipped with Amerex SafetyNet fire suppression system panel/controller units. These buses have gas detection electronics that may be disabled without providing the operator with a warning of a system malfunction. Affected display panel/controller units were also provided as replacement parts for warranty claims, part numbers 16389, 24109, 24918, 24926 and 24927.

Why it matters: If not corrected, the fire suppression systems on certain CNG-powered buses may fail to indicate the presence of a natural gas (methane) leak. In such cases, the driver will not receive a fault code indicating that the Gas Detection electronics have been disabled. This may increase the risk of asphyxiation, fire, or explosion.

Remedy

Gillig will notify owners, and Amerex representatives will replace the Operator Display Panel/Controllers, free of charge. The recall began January 20, 2017. Owners may contact Gillig customer service at 1-800-735-1500.

Owner notification: January 20, 2017 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 16V662000

Component
SERVICE BRAKES, AIR
Report received
September 14, 2016
Potential units
34campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain model year 2014-2016 Gillig 29-foot Low Floor transit buses manufactured November 20, 2014, to February 11, 2016. These buses, equipped with disc brakes, have rear brake hoses that can rub chassis components and fray.

Why it matters: A frayed hose may leak air, causing the rear brake(s) to lock up unexpectedly, or fail to operate when the brakes are applied. Either scenario increases the risk of a crash.

Remedy

Gillig will provide fleets new rear brake hoses, fittings, clamps, and hardware along with instructions on how to reorient the hoses using the new fittings, and reimburse them for their labor, free of charge. The recall began on September 29, 2016. Owners may contact Gillig customer service at 1-800-735-1500.

Owner notification: September 29, 2016 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 16V451000

Component
EXTERIOR LIGHTING
Report received
June 21, 2016
Potential units
112campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain model year 2012-2016 Lowfloor diesel-electric hybrid vehicles manufactured March 6, 2012, to June 7, 2016. The affected vehicles are equipped with stop lamp activation that may inadvertently flash the rear brake lights. As such, these vehicles do not comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) No. 108, "Lamps, Reflective Devices, and Assoc. Equipment.".

Why it matters: Flashing brake lights may cause confusion to other drivers, increasing the risk of a crash.

Remedy

Gillig will notify owners, and dealers will install a new software update, free of charge. The recall began on July 2016. Owners may contact Gillig customer service at 1-800-735-1500.

Owner notification: July 1, 2016 · Filing manufacturer: Gillig LLC

CAMPAIGN

NHTSA 16V320000

Component
VISIBILITY
Report received
May 18, 2016
Potential units
34campaign-wide
Defect and consequence

Defect: Gillig LLC (Gillig) is recalling certain 2016 Low Floor vehicles manufactured March 3, 2016, to April 21, 2016. The driver's side window on the affected vehicles may block too much light, thereby decreasing the driver's visibility. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 205, "Glazing Materials.".

Why it matters: Reduced driver's visibility can increase the risk of a crash.

Remedy

Gillig will notify owners, and dealers will install compliant driver's windows, free of charge. The recall began on June 20, 2016. Owners may contact Gillig customer service at 1-800-735-1500.

Owner notification: June 20, 2016 · Filing manufacturer: Gillig LLC

02 / COMPONENT BREADTH

What defects are listed for the 2016 Gillig Low Floor?

The most frequent component groups in 2016 Gillig Low Floor campaign records are Exterior Lighting (6), Steering (3), Service Brakes, Air (2), Electrical System (2), Visibility (1); these counts describe filed campaigns rather than observed failure rates.
Exterior Lighting6
Steering3
Service Brakes, Air2
Electrical System2
Visibility1