2013 Altec AH75 recall campaigns
NHTSA 16V023000
- Component
- ELECTRICAL SYSTEM
- Report received
- January 20, 2016
- Potential units
- 195campaign-wide
Defect and consequence
Defect: Altec Industries (Altec) is recalling certain model year 2010-2015 AH75, AH85, and AH100 Aerial Devices manufactured January 10, 2008, to December 31, 2015. The affected units have a hydraulic pressure control valve that may allow the aerial device to move even when not told to do so.
Why it matters: An aerial device that moves unexpectedly increases the risk of injury to the operator.
Remedy
Altec will notify owners, and dealers will replace the hydraulic pressure control valves, free of charge. The recall began on March 15, 2016. Owners may contact Altec customer service at 1-205-991-7733.
Owner notification: March 15, 2016 · Filing manufacturer: Altec Industries Inc.
NHTSA 14V001000
- Component
- EQUIPMENT
- Report received
- January 2, 2014
- Potential units
- 168campaign-wide
Defect and consequence
Defect: Altec Industries, Inc. (Altec) is recalling certain model year 2010-2013 AH75, AH85, and AH100 vehicles manufactured from April 1, 2010, through November 20, 2013. Moisture may get into the control module plug and result in inadvertant movement of the boom or platform.
Why it matters: The unexpected movement increases the risk of injury to the operator or those nearby.
Remedy
Altec will notify owners and dealers will replace the control module wiring harness, free of charge. The recall will begin on April 14, 2014. Customers may contact Altec at 1-877-462-5832. Altec's number for this recall is CSN 592.
Owner notification: April 14, 2014 · Filing manufacturer: Altec Industries Inc.
NHTSA 13V378000
- Component
- ELECTRICAL SYSTEM
- Report received
- August 21, 2013
- Potential units
- 263campaign-wide
Defect and consequence
Defect: Altec is recalling certain model year 2005-2013 AH75/85/100 aerial devices manufactured April 2005 through April 2013; and equipped with current leakage monitoring systems. The cable for the current leakage monitoring system may be too long and may breach the gap provided by the lower boom fiberglass insert chassis insulating system.
Why it matters: If the gap is breached, then the boom may conduct electrical current, increasing the risk of electrical shock to the operator.
Remedy
Altec will notify owners and dealers will inspect and properly secure the leakage monitor cable. The recall is expected to begin during September 2013. Altec's recall number is CSN 585. Owners may contact Altec at 1-877-462-5832.
Owner notification: Date not reported · Filing manufacturer: Altec Industries Inc.