01 / OFFICIAL CAMPAIGNS
2010 Terex Digger Derrick recall campaigns
NHTSA 17V320000
- Component
- ELECTRICAL SYSTEM, EQUIPMENT
- Report received
- May 15, 2017
- Potential units
- 58campaign-wide
Defect and consequence
Defect: Terex South Dakota (TSD) is recalling certain 2007-2016 vehicles equipped with Terex C4000, FC, HR, HRX, SCM, TC, TCX, TL, TPL, and XT aerial devices and digger derricks used for utility line work. In the event of a short circuit of a tool plugged into the onboard electrical socket, the GFPE breaker may not trip at the proper current before the user receives a shock.
Why it matters: Without proper protection against electrical shock, the user has a greater risk of injury.
Remedy
TSD will notify owners, and dealers will replace the breakers with GFCI breakers that will trip at a lower current, free of charge. The recall began on June 27, 2017. Owners may contact TSD Customer Service Department at 1-800-982-8975. TSD's number for this recall is SN658.
Owner notification: June 27, 2017 · Filing manufacturer: Terex South Dakota, Inc.
NHTSA 13V089000
- Component
- EQUIPMENT, STRUCTURE
- Report received
- March 7, 2013
- Potential units
- 261campaign-wide
Defect and consequence
Defect: Terex South Dakota, Inc. (Terex) is recalling certain model year 1999-2012 XL4000 Digger Derrick utility trucks. The shims and spacers used to adjust the length of the hydraulic cylinder may give, causing the rod eye and threads to fatigue while lifting loads.
Why it matters: The hydraulic cylinder may separate from the digger derick arm, allowing it to collapse without warning, increasing the risk of injury to the operator or those nearby.
Remedy
Terex will notify owners, and dealers will inspect and replace the rod eye and threads, as necessary. The existing shims and spacer will be replaced with a hardened spacer. All repairs will be made at no charge to the owner. The recall began on May 23, 2013. Owners may contact Terex at 1-605-882-4000.
Owner notification: May 23, 2013 · Filing manufacturer: Terex South Dakota, Inc.
NHTSA 11V048000
- Component
- EQUIPMENT
- Report received
- January 20, 2011
- Potential units
- 254campaign-wide
Defect and consequence
Defect: Terex is recalling certain model year 2008-2010 aerial device and digger derrick utility vehicles manufactured from june, 2008 through november, 2010. the lanyard anchors were not heat treated properly and may fracture.
Why it matters: Failure of the lanyard anchor could occur increasing the risk of personal injuries or death.
Remedy
Dealers will replace the lanyard anchors with a new part free of charge. the safety recall began on february 11, 2011. owners may contact terex at 1-605-884-3892.
Owner notification: February 11, 2011 · Filing manufacturer: TEREX UTILITIES SOUTH, INC.