OFFICIAL CAMPAIGN FILE
NHTSA campaign 18V691000
NHTSA campaign 18V691000 covers 38 published year-and-model reports from 1 makes in this index and lists 923 potentially affected units campaign-wide. VIN eligibility must be checked separately.
Report received October 3, 2018 · Snapshot September 21, 2026
01 / DEFECT RECORD
What NHTSA campaign 18V691000 says
Defect summary
Spartan Motors USA (Spartan) is recalling certain 2001-2019 Spartan MetroStar and Gladiator emergency vehicles. The mounting fasteners for the Emergency Medical Service (EMS) cabinets may not be the correct size, allowing the cabinets to break free from their mountings in the event of a crash.
Consequence summary
If the EMS cabinets become loose during a crash, the cabinets may become projectiles, increasing the risk of injury.
02 / CORRECTIVE ACTION
Remedy for NHTSA campaign 18V691000
Spartan will notify owners, and dealers will replace the incorrect size fasteners with the correct fasteners, free of charge. The recall began November 30, 2018. Owners may contact Spartan customer service at 1-800-543-5008. Spartan's number for this recall is 18030.
- Owner notification
- November 30, 2018
- Filing manufacturer
- Spartan Motors USA
- Component groups
- EQUIPMENT