NHTSA DATA SNAPSHOT · SEP 21 2026MODEL MATCH ≠ VIN MATCHCHECK A VIN AT NHTSA ↗
RECALLROADTHE CAMPAIGN RECORD

OFFICIAL CAMPAIGN FILE

NHTSA campaign 14V153000

NHTSA campaign 14V153000 covers 21 published year-and-model reports from 3 makes in this index and lists 1,373,177 potentially affected units campaign-wide. VIN eligibility must be checked separately.

Report received March 31, 2014 · Snapshot September 21, 2026

01 / DEFECT RECORD

What NHTSA campaign 14V153000 says

NHTSA campaign 14V153000 identifies STEERING and states that If power steering assist is lost, greater driver effort would be required to steer the vehicle at low speeds, increasing the risk of a crash.

Defect summary

General Motors LLC (GM) is recalling certain model year 2004-2006 and 2008-2009 Chevrolet Malibu, 2004-2006 Malibu Maxx, 2009-2010 HHR (non-turbo), 2010 Cobalt, 2008-2009 Saturn Aura and 2004-2007 Ion, and 2005-2009 Pontiac G6. In the affected vehicles, there may be a sudden loss of electric power steering (EPS) assist that could occur at any time while driving.

Consequence summary

If power steering assist is lost, greater driver effort would be required to steer the vehicle at low speeds, increasing the risk of a crash.

02 / CORRECTIVE ACTION

Remedy for NHTSA campaign 14V153000

For NHTSA campaign 14V153000, the filed corrective action says: GM will notify owners, and dealers will perform one of four bulletins. Parts are not currently available. GM expects to send an interim notification around May 28, 2014. When parts are available, owners will be mailed a second letter to come in to have the applicable bulletin applied. Bulletin 14115 covers model year 2004-2007 Saturn Ion, 2009-2010 Chevrolet HHR and 2010 Chevrolet Cobalts. Dealers will replace the EPS motor. Bulletin 14116 covers model year 2004-2006 Chevrolet Malibu and Malibu Maxx, 2005-2006 Pontiac G6 and 2008-2009 Chevrolet Malibu, Pontiac G6 and Saturn Aura built from March 1, 2008, through June 27, 2008. Dealers will replace the torque sensor assembly. Bulletin 14117 covers model year 2008 Chevrolet Malibu, Pontiac G6 and Saturn Aura built from February 1, 2008, through February 28, 2008. Dealers will replace the torque sensor assembly and EPS motor controller unit. Bulletin 14118 covers model year 2008 Chevrolet Malibu, Pontiac G6 and Saturn Aura built from October 1, 2007, through January 31, 2008. Dealers will replace the EPS motor controller unit. The recall began on July 17, 2014. Owners may contact Chevrolet at 1-800-630-2438, Saturn at 1-800-553-6000, and Pontiac at 1-800-620-7668. GM's number for this recall is N140115. Note: GM bulletin number 14119 will be implemented for model year 2006-2008 and early production of 2009 Chevrolet HHR (non-turbo) and model year 2003 Saturn ION to provide EPS Motor replacement for the life of the vehicle.

GM will notify owners, and dealers will perform one of four bulletins. Parts are not currently available. GM expects to send an interim notification around May 28, 2014. When parts are available, owners will be mailed a second letter to come in to have the applicable bulletin applied. Bulletin 14115 covers model year 2004-2007 Saturn Ion, 2009-2010 Chevrolet HHR and 2010 Chevrolet Cobalts. Dealers will replace the EPS motor. Bulletin 14116 covers model year 2004-2006 Chevrolet Malibu and Malibu Maxx, 2005-2006 Pontiac G6 and 2008-2009 Chevrolet Malibu, Pontiac G6 and Saturn Aura built from March 1, 2008, through June 27, 2008. Dealers will replace the torque sensor assembly. Bulletin 14117 covers model year 2008 Chevrolet Malibu, Pontiac G6 and Saturn Aura built from February 1, 2008, through February 28, 2008. Dealers will replace the torque sensor assembly and EPS motor controller unit. Bulletin 14118 covers model year 2008 Chevrolet Malibu, Pontiac G6 and Saturn Aura built from October 1, 2007, through January 31, 2008. Dealers will replace the EPS motor controller unit. The recall began on July 17, 2014. Owners may contact Chevrolet at 1-800-630-2438, Saturn at 1-800-553-6000, and Pontiac at 1-800-620-7668. GM's number for this recall is N140115. Note: GM bulletin number 14119 will be implemented for model year 2006-2008 and early production of 2009 Chevrolet HHR (non-turbo) and model year 2003 Saturn ION to provide EPS Motor replacement for the life of the vehicle.

Owner notification
July 17, 2014
Filing manufacturer
General Motors LLC
Component groups
STEERING

03 / PUBLISHED VEHICLES

Vehicles listed under NHTSA campaign 14V153000

RecallRoad links 21 year-and-model reports associated with NHTSA campaign 14V153000; the list reflects published source rows, not individual VIN coverage.